Heos Pro solution - fascia 1

 

 

Your green answer for
PLUG-IN CABINETS

Designed to embrace CAREL’s “continuous modulation” approach, driving an EEV stepper valve and CAREL PSD inverter, this controller allows features Bluetooth and Ethernet connections. Operation with both propane (R-290) and subcritical or transcritical CO2 (R-744).

Designed to embrace CAREL’s “continuous modulation” approach, driving an EEV stepper valve and CAREL PSD inverter, this controller allows features Bluetooth and Ethernet connections. Operation with both propane (R-290) and subcritical or transcritical CO2 (R-744).

  • Natural refrigerants, CO2 and propane
  • Food preservation at stable temperature
  • Advanced connectivity, Bluetooth and Ethernet
  • A3 ready (compliance with EN 60 335-2-89: 2010 Annex BB)
  • Natural refrigerants, CO2 and propane
  • Food preservation at stable temperature
  • Advanced connectivity, Bluetooth and Ethernet
  • A3 ready(compliance with EN 60 335-2-89: 2010 Annex BB)

 

 

Heos Pro solution - fascia 2

 

Heos PRO

CAREL's consolidated experience in refrigeration and with natural refrigerants has allowed the development of highly-efficient semi-plugin showcase solutions, guaranteeing a considerable reduction in environmental impact, cutting direct emissions thanks to natural refrigerants and indirect emissions through continuous modulation.

DOWNLOAD BROCHURE read WHITe paper

Heos PRO

 

CAREL's consolidated experience in refrigeration and with natural refrigerants has allowed the development of highly-efficient semi-plugin showcase solutions, guaranteeing a considerable reduction in environmental impact, cutting direct emissions thanks to natural refrigerants and indirect emissions through continuous modulation.

DOwnload brochure
read white paper
 

 

Heos Pro solution - fascia 3

 

Single MT/LT circuit

 

R-290 Multiple circuit on-off

 

CO2 (MT/LT subcritical or MT Transcritical) Single Circuit:

  • One expansion valve
  • High pressure and superheat control with one valve (transcritical only)
  • Optimal transcritical pressure (transcritical only)

R-290 Single Circuit:

  • Up to 150/500g
  • Small loads
  • MT/LT application
  • EN60079 compliant

R-290 Multiple Circuit on-off:

  • Up to 3 ref. circuits
  • All types of cooling loads
  • MT/LT applications
  • EN 60079 compliant

Single MT/LT circuit

 

CO2 (MT/LT subcritical or MT Transcritical) Single Circuit:

  • One expansion valve
  • High pressure and superheat control with one valve (transcritical only)
  • Optimal transcritical pressure (transcritical only)

R-290 Single Circuit:

  • Up to 150/500g
  • Small loads
  • MT/LT application
  • EN60079 compliant

 

R-290 Multiple circuit on-off

 

R-290 Multiple Circuit on-off:

  • Up to 3 ref. circuits
  • All types of cooling loads
  • MT/LT applications
  • EN 60079 compliant

 

 

Heos components - solution - fascia 4

 

Heos Pro components

Controller

  • Software available for propane and CO2
  • Tailor-made software solution
  • Single hardware for both propane and CO2 applications
  • A3 ready (compliance with EN 60 335-2-89: 2010 Annex BB)

Inverter

  • PEC version available
  • Class B firmware

EEV stepper valve

  • Continuous equipercentile modulation
  • Top performance during temperature pull down
  • Compressor safety functions

Probes

  • Wide range of pressure and temperature probes
  • Different cable lengths available
  • Suitable for high pressure/temperature
  • Weld-on version for pressure probes

 

CO2 and Propane DC Inverter Rotary Compressor

  • Wide modulation range for efficiency and performance
  • Low noise and vibrations
  • Compact dimensions

Standard Retail HMI

  • NFC and Bluetooth
  • Extensive customisation options
  • Backlit buttons and multicolour icons

 

Controller

  • Software available for propane and CO2
  • Tailor-made software solution
  • Single hardware for both propane and CO2 applications
  • A3 ready (compliance with EN 60 335-2-89: 2010 Annex BB)

Inverter

  • PEC version available
  • Class B firmware
 

EEV stepper valve

  • Continuous equipercentile modulation
  • Top performance during temperature pull down
  • Compressor safety functions
 

Probes

  • Wide range of pressure and temperature probes
  • Different cable lengths available
  • Suitable for high pressure/temperature
  • Weld-on version for pressure probes

R290 DC Inverter Rotary compressor

  • Wide modulation range for efficiency and performance
  • Low noise and vibrations
  • Compact dimensions

Standard Retail HMI

  • NFC and Bluetooth
  • Extensive customisation options
  • Backlit buttons and multicolour icons

 

Heos Pro connectivity - solution - fascia 5

 

Advanced connectivity

 

Heos Pro is designed to embrace the advanced connectivity. The board can be connected via Ethernet (Modbus TCP/IP) to maximise connection speed.

 

The HMI connection via Bluetooth or NFC allows parameters 

configuration and commissioning directly from the APPLICA app.

 

 

Script Non Cancellare - Heos Pro solution